Local Repair FinderSalt Lake City home repair guide

Furnace not working in Salt Lake City: what should you check?

Salt Lake City & Salt Lake County · Reviewed November 2026 · Checked against 7 public sources

Most no-heat calls start with something small. Look at the thermostat mode, the air filter, the breaker and the furnace's own power switch. If the burners still won't run, book a heating technician. A gas smell changes the plan: get outside, then phone Enbridge Gas Utah on 1-800-767-1689 and 911. The airport's normal January low is 24.2 °F, so don't let it wait overnight.

Key facts

Gas smell
Enbridge Gas Utah, 1-800-767-1689, and 911. Leave first
Contractor license
H100 HVAC Contractor, issued by Utah DOPL
Permit
Needed to install or alter a heating system in Salt Lake City
New gas furnace
$4,000–$8,000 (national, Fixr)
2026 Enbridge rebate
$300 or $350, by AFUE rating
Normal January low
24.2 °F at the airport (NOAA 1991-2020)

What is it usually?

SymptomLikely causeYour move
Thermostat screen is blankFlat batteries, or the furnace has lost powerFit new batteries. Then look at the breaker
Fan runs, air feels coolFan set to On, or the burners aren't lightingSwitch the fan to Auto. No change? Call
Heat starts, then quits fastClogged filter, or a safety sensor is shutting it downFit a clean filter. Don't keep restarting it
Total silenceTripped breaker, or the furnace switch got bumpedOne reset. Flip the switch up
Rotten-egg odorPossible gas leakGo outside. Call Enbridge from there

What can you safely check yourself?

  1. Thermostat. Is it on Heat? Is the target a few degrees over the room reading? A dim display wants new batteries.
  2. Filter. Slide it out. Grey and fuzzy means it is starving the furnace of air. Put in a fresh one, same size, arrow toward the furnace.
  3. Breaker. Find the one marked furnace or air handler. Sitting between On and Off? Push it fully off, then on. A single attempt is the limit.
  4. Furnace switch. Near the unit there is often a plain wall switch that looks like a light switch. Someone may have knocked it. It should be up.
  5. Four checks done and the house is still cold? Ring a local heating company now. The remaining steps can wait until you are off the phone.

    Phone line opening soon

    Have this ready when you call

    • Your address
    • What the system is doing (no heat, no cooling, a noise, a leak)
    • Roughly how old the unit is
  6. Registers and returns. Open the floor and wall vents. Pull rugs, boxes and couches off the big return grille.
  7. Pipes on the outside wall. Newer furnaces breathe through plastic pipes that exit the house. From outdoors, brush away snow, ice or leaves at the openings. Hands only. Nothing goes inside the pipe.
  8. Stay warm the safe way. Keep space heaters clear of bedding and curtains. Never heat a room with the oven, a grill or a camp stove. Worried about plumbing in a cold house? See frozen pipes.
Basement furnace with its front panel removed

When should you stop and call a pro?

  • The breaker flips off again after your single reset.
  • The furnace lights, runs briefly and shuts down, over and over.
  • You hear banging, scraping or a loud hum from the cabinet.
  • There is a burnt or electrical smell at a vent.
  • A carbon monoxide alarm sounds. Everyone goes outside and you dial 911.
  • Every check passes and the air is still cold.

Past this list, the work means removing covers, touching gas parts or testing live wiring. Leave the cabinet shut. Leave the pilot and the gas controls alone.

Want a price for your home? Call a local heating & cooling pro for a written quote.

Phone line opening soon

Who do you call about a gas smell?

Not a furnace company. Enbridge Gas Utah, formerly Dominion Energy Utah, takes leak reports on its 24-hour line, 1-800-767-1689. 911 works too. Walk out before you dial. Don't flip lights, don't touch appliances, don't use a phone indoors, don't start a car close to the house. Prop doors open on the way out only if it costs you no time. Leave the hunt for the leak to the utility crew.

How cold is a Salt Lake City winter night?

NOAA's 1991-2020 normals give the airport a January low of 24.2 °F. That is the average, so some nights sit under it. A house without heat cools quickly at that temperature. If small children or older relatives live with you, plan a warm place for them before the technician arrives.

Does the fix need a permit?

Salt Lake City Building Services says a permit is required for installing or altering heating, ventilation, and air conditioning systems. A full furnace swap alters the system. The city's FAQ does not spell out small repairs, and this guide has no ruling on them. Ask the contractor, and get the answer on the quote. Applications can be sent in online through the city's Citizen Access Portal.

Which license should you ask for?

Utah's Division of Professional Licensing, known as DOPL, licenses heating contractors. The classification is H100 HVAC Contractor. Type the company name into the DOPL lookup before anyone starts. DOPL's phone is 801-530-6628.

What does it cost?

For repairs, this guide has no verified Salt Lake City price. Ask for the diagnosis fee and the repair total in writing. For a whole new gas furnace, Fixr's national range is $4,000 to $8,000. That figure is national, not local. Enbridge's 2026 ThermWise rebate is $300 for a furnace rated AFUE 95% to 97.4% and $350 for AFUE 97.5% or higher with an ECM, in existing homes. More on the furnace cost page and the rebates page.

What a repair usually costs

National ranges from cost publishers, not Salt Lake City quotes. The fault decides the price, so ask for it in writing before work starts.

JobNational rangeSource
Furnace repair$349 to $650Fixr, updated Aug 2025

When you call: 4 questions to ask

  1. Is the diagnostic or trip fee credited toward the repair?
  2. Will you size a new system with a load calculation rather than the old unit's size?
  3. Will you pull the Salt Lake City permit, and what's your Utah DOPL license number?
  4. Does this equipment qualify for an Enbridge Gas Utah or Rocky Mountain Power rebate, and who files it?

A fair written quote shows model numbers and efficiency, the permit and inspection, removal of the old unit, and parts and labor warranty. Check any contractor's license on Utah's DOPL lookup before work starts.

What happens when you call

  1. You're connectedStraight to a local heating & cooling pro that serves your area and takes calls like yours.
  2. You get a priceDescribe the problem, ask for a written quote and their license number. No obligation.

Common questions

Why is my furnace blowing cold air?

Often the thermostat fan is set to On, so the blower runs between heating cycles. Set it to Auto. A clogged filter can also make the furnace shut its burners off early. If neither fixes it, have a technician look.

Who do I call for no heat in Salt Lake City?

A heating contractor, unless you smell gas. For a gas smell, leave the house and call Enbridge Gas Utah at 1-800-767-1689 and 911. Check the contractor's H100 license on the DOPL lookup.

Can I reset my furnace myself?

You can reset a tripped breaker one time and make sure the furnace's wall switch is on. Don't open the cabinet, and don't try to relight anything. If it trips again, stop.

Is there a rebate if the furnace has to be replaced?

In 2026 Enbridge Gas Utah pays $300 for a gas furnace rated AFUE 95% to 97.4% and $350 for AFUE 97.5% or higher with an ECM. The form covers existing homes.

Related guides

Sources

  1. NOAA NCEI: 1991-2020 monthly climate normals, Salt Lake City International Airport
  2. Enbridge Gas Utah: Smell gas?
  3. Utah Public Service Commission: Enbridge Gas Utah customer communications plan and rebranding update
  4. Salt Lake City Building Services: Frequently asked questions
  5. Utah Division of Professional Licensing: Apply for a general contractor license
  6. Fixr: Natural gas furnace cost
  7. Enbridge Gas Utah: 2026 ThermWise appliance rebates, heating (Utah)

Costs are typical ranges. Your quote depends on your home. Rules and rebates change; check the original source before you rely on a figure. Something wrong? Tell us via the contact on the Impressum page.